Do you need a Laser Protection Adviser?
Yes, if the clinic uses a Class 3B or Class 4 laser or an IPL system. Class 3B and Class 4 lasers, as classified under BS EN 60825-1, can injure the eye and skin, and IPL systems carry comparable risks. MHRA guidance recommends that any practice using this equipment appoints a Laser Protection Adviser.
The legal duty sits with the employer. The Control of Artificial Optical Radiation at Work Regulations 2010 require employers to assess the risk of exposure to laser and IPL light and to put controls in place. The Management of Health and Safety at Work Regulations 1999 require a suitable and sufficient risk assessment and access to competent health and safety advice. A Laser Protection Adviser is the usual way a clinic obtains that advice.
How the requirement is enforced depends on where the clinic is. Local authority licence conditions in England, and the national regulators in Wales and Northern Ireland, commonly make an adviser a condition of operating. The rules by nation are set out below.
What a compliant clinic holds
MHRA guidance describes the arrangements a clinic is expected to have in place. Inspectors and licensing officers usually ask to see the following.
- A Laser Protection Adviser (LPA). A specialist who advises the clinic on laser and IPL safety, writes or reviews the Local Rules and risk assessment, and audits the arrangements. The LPA is usually external to the clinic.
- A Laser Protection Supervisor (LPS). A member of the clinic’s own staff who makes sure the Local Rules are followed day to day and keeps the laser safety file up to date.
- Local Rules. Written safe working procedures for each device and treatment room. Every authorised user reads them, has them explained, and signs a declaration.
- A risk assessment. A written record of the hazards to clients and staff from each device, and the controls in place, as required by the Management of Health and Safety at Work Regulations 1999 and the Control of Artificial Optical Radiation at Work Regulations 2010.
- A register of authorised users. The named people allowed to operate each laser or IPL, with the training each person has completed.
- Core of Knowledge and device training. A Core of Knowledge course in laser and IPL safety for each operator, plus training from the manufacturer or supplier on each device.
- A treatment register. A record of every treatment: client, operator, device, settings and any adverse effect.
- A laser controlled area and signage. A defined treatment room with warning signs at the entrance, controlled access, covered or non-reflective surfaces where needed, and protective eyewear matched to the wavelength of each device.
Most of these items live in a single laser safety file kept at the clinic. The Local Rules and the risk assessment are specific to the clinic’s own rooms and devices; a generic template does not meet the guidance. Summaries of the underlying legislation and standards are on the standards and legislation page.
Rules by nation
The safety arrangements above apply across the UK. Who regulates the clinic, and how, differs between England, Scotland, Wales and Northern Ireland. Requirements change, so confirm them with your local authority or regulator before opening or adding a device.
England
Cosmetic laser and IPL treatments are mainly regulated through local authority licensing, and conditions vary by council. In London, premises offering laser and IPL treatments usually need a special treatment licence from the borough. Licence conditions commonly require a Laser Protection Adviser, Local Rules written by the adviser, a named Laser Protection Supervisor and Core of Knowledge training for operators. Some councils name the adviser certification bodies they accept, so check your council’s conditions before appointing an adviser.
Where lasers or IPL are used to diagnose or treat disease, disorder or injury, or for surgical procedures, the service may need to register with the Care Quality Commission (CQC). Purely cosmetic treatments are generally outside CQC registration.
Scotland
Independent clinics run by doctors, dentists, nurses, midwives or dental care professionals register with Healthcare Improvement Scotland. Other laser and IPL providers should check with their local authority for any licensing requirements. The MHRA guidance and the Control of Artificial Optical Radiation at Work Regulations 2010 apply in all cases.
Wales
Healthcare Inspectorate Wales (HIW) regulates services providing treatment with Class 3B or Class 4 lasers or IPL, which register with HIW as independent hospitals. HIW inspects the laser safety arrangements, including the appointment of a Laser Protection Adviser, Local Rules and the risk assessment.
Northern Ireland
Establishments using Class 3B or Class 4 lasers or IPL register with the Regulation and Quality Improvement Authority (RQIA). RQIA inspections check that a Laser Protection Adviser is appointed, that Local Rules and a risk assessment written by the adviser are in place, and that authorised users are trained.
The audit and certificate
An LPA audit is carried out by a Laser Protection Adviser certified by the Association and listed on the Register of Certified Laser Protection Advisers.
- Request an audit. Use the booking page or choose an adviser from the Register. A member of the Association contacts the clinic to agree the scope and a date.
- Site visit. The adviser inspects each treatment room and device, checks eyewear and signage, and talks to the Laser Protection Supervisor and authorised users.
- Local Rules and risk assessment. The adviser writes or reviews the Local Rules and the risk assessment for the clinic’s own rooms, devices and treatments.
- Audit against the checklist. The adviser completes the Association’s audit checklist. Each gap becomes an action with an owner and a due date.
- Certificate of LPA Audit. When the audit is complete, the clinic receives a certificate valid for 24 months. Each certificate carries a number and a QR code that links to a public check.
- Annual renewal. The adviser re-audits before the certificate expires and updates the documents when rooms, devices, treatments or staff change.
The certificate confirms that, on the date of the audit, the premises and equipment listed were assessed against the Association’s checklist. It does not replace a licence or registration. Day-to-day compliance remains the responsibility of the employer, the Laser Protection Supervisor and the authorised users. Anyone can confirm a certificate is current on the Check a certificate page.
The Laser Safety Register platform
After the audit, the clinic keeps its laser safety file in the Laser Safety Register, a secure online platform shared between the clinic and its adviser.
- Clinic portal. Local Rules, the risk assessment, the audit report and the certificate in one place, with a signed declaration from every authorised user.
- Treatment records. A guided record for each client, one step at a time: informed consent, health questionnaire, skin type and patch test, pre-treatment safety checks, and the treatment record with device settings.
- Clinic records. Equipment servicing, training, eyewear inspections and incidents, held against the device or person they relate to.
- Audit actions. Open actions from the audit, marked complete by the clinic and checked by the adviser.
Because the records sit alongside the Local Rules and the certificate, the clinic can show an inspector or licensing officer the whole file in one place. Access is by invitation from the clinic’s adviser.
Frequently asked questions
Do I need a laser protection advisor for laser hair removal?
MHRA guidance recommends appointing a Laser Protection Adviser for any Class 3B or Class 4 laser or IPL, including those used for hair removal. Many local authority licences in England require one, and clinics registered with Healthcare Inspectorate Wales or the Regulation and Quality Improvement Authority in Northern Ireland are expected to have one. Appoint an adviser before treating clients.
What is the difference between a Laser Protection Adviser and a Laser Protection Supervisor?
The Laser Protection Adviser is a specialist, usually external, who advises on laser safety, writes or reviews the Local Rules and risk assessment, and audits the clinic. The Laser Protection Supervisor is a member of the clinic’s staff who makes sure the Local Rules are followed every day.
Who is legally responsible for laser safety in the clinic?
The employer. MHRA guidance states that the employer may delegate tasks to the Laser Protection Adviser and the Laser Protection Supervisor but keeps the legal responsibility for safety.
How often should Local Rules and the risk assessment be reviewed?
MHRA guidance says the Laser Protection Supervisor should review the risk assessment every year and the Laser Protection Adviser should audit it at least every two years, or sooner if equipment or procedures change. Local Rules are updated whenever a device, room or treatment changes, and staff sign them again. The Association’s certificate runs for 24 months, in line with that two-yearly audit. Local Rules and the risk assessment are still reviewed every 12 months, and the Laser Safety Register reminds the clinic when a review is due.
Is the Certificate of LPA Audit a licence?
No. The certificate is issued under the Association’s own scheme. It records that a certified Laser Protection Adviser audited the clinic on a given date. It does not replace a local authority licence or registration with a regulator.
Can a client or inspector check our certificate?
Yes. Each certificate has a number and a QR code. Anyone can enter the number on the Check a certificate page to see whether it is current. Audit certificate numbers begin AUD-.
Do IPL systems need the same safety arrangements as lasers?
Yes, in practice. IPL light is covered by the Control of Artificial Optical Radiation at Work Regulations 2010, and MHRA guidance applies the same arrangements to IPL as to Class 3B and Class 4 lasers: an adviser, Local Rules, a risk assessment, trained authorised users and a controlled area.
Last checked: 21 October 2026. This page summarises guidance and is not legal advice. Sources: MHRA laser guidance (2015) (opens in a new tab), the Control of Artificial Optical Radiation at Work Regulations 2010, the Management of Health and Safety at Work Regulations 1999 and BS EN 60825-1.