What the audit checks
The Adviser works through the Association’s audit checklist for each treatment room and each laser or IPL device. The checklist has 13 sections.
- Laser Controlled Area. How the treatment area is defined, signed and secured, and how windows, mirrors and other reflective surfaces are controlled.
- Laser protective eyewear and PPE. Eyewear for every wavelength in use, its markings, condition, storage and cleaning, and eye protection for the client.
- Laser and IPL equipment. The equipment inventory, classification and safety labels, user manuals, emergency stop, pre-use checks and service records.
- Security and unauthorised use. Key control, passwords and access codes, and restriction of operation to Authorised Users.
- Staff, training and authorisation. The Laser Protection Supervisor, the Register of Authorised Users, Core of Knowledge and device training, and signed Local Rules.
- Local Rules, risk assessment and treatment protocols. Whether each document is current, specific to the clinic and its devices, and within its review period.
- Client safety and clinical records. Consultation, medical history, skin type, patch tests, informed consent and the treatment parameters recorded for each session.
- Fire safety. Fire risk from laser use, combustible materials, alcohol-based skin preparations and access to firefighting equipment.
- Laser plume, COSHH and hazardous substances. Assessment of airborne contaminants, plume extraction where required and maintenance of filters.
- Infection prevention and hygiene. Hand hygiene, gloves and other PPE, and cleaning of treatment surfaces and equipment.
- General environment and premises. Condition of the treatment room, working space, ventilation and temperature.
- Incidents and emergency arrangements. Emergency shutdown, procedures for suspected eye exposure and burns, and incident and near-miss reporting.
- Insurance, registration and governance. Insurance cover for the treatments offered, local authority licensing or registration, and clinic policies.
What you receive
- A written audit report recording the answer to each checklist question, with the Adviser’s notes.
- An action plan in which every gap becomes an action with an owner and a due date.
- Local Rules and a laser safety risk assessment written for your rooms and devices, where these are needed.
- A Certificate of LPA Audit, valid for 24 months, with a number beginning AUD- and a QR code.
- Access to the Laser Safety Register, the online platform where the clinic keeps its laser safety file, collects signatures on the Local Rules and closes actions.
Anyone, including a client or an inspector, can enter the certificate number on the Check a certificate page to see whether it is current.
The certificate records that, on the date of the audit, the premises and equipment listed were assessed against the Association’s checklist. Day-to-day compliance remains with the clinic’s Laser Protection Supervisor and Authorised Users.
How it works, step by step
- Book. Submit the booking form, naming an Adviser from the Register if you have one in mind. A member of the Association contacts you to agree the date and the scope.
- Prepare. Gather what you already hold: device manuals and service records, any existing Local Rules and risk assessment, your list of Authorised Users with their training certificates, and your insurance documents.
- Site visit. The Adviser inspects each treatment room and device, reviews your documents and speaks to the Laser Protection Supervisor and operators.
- Report and actions. The Adviser records the outcome and issues the report and action plan. The clinic marks each action as done and the Adviser checks it.
- Certificate. The Certificate of LPA Audit is issued with the report and states the audit outcome.
- Renewal. The Adviser re-audits before the certificate expires, and sooner if devices, rooms or procedures change.
What inspectors and councils look for
Clinics using Class 3B or Class 4 lasers, as classified under BS EN 60825-1, or IPL systems have duties under the Control of Artificial Optical Radiation at Work Regulations 2010 and the Management of Health and Safety at Work Regulations 1999 to assess and control the risk. The MHRA’s 2015 guidance sets out how clinics usually meet those duties. A summary of each is on the standards page.
Who inspects the clinic depends on where it is and what it does:
- England. Cosmetic laser and IPL premises are mostly licensed by the local authority, for example under special treatment licensing in London, and conditions vary by council. Clinics carrying out regulated medical activity register with the Care Quality Commission.
- Scotland. Independent clinics register with Healthcare Improvement Scotland.
- Wales. Services using Class 3B or Class 4 lasers or IPL register with Healthcare Inspectorate Wales.
- Northern Ireland. Clinics using these devices register with the Regulation and Quality Improvement Authority (RQIA).
Published council licence conditions and RQIA inspection reports ask for the same core documents: Local Rules prepared by the LPA and signed by operators, a dated risk assessment with a review date, a named Laser Protection Supervisor, a register of Authorised Users with training records, treatment records, and service records for each device. Some councils also expect the LPA to visit before treatments begin and to be told when the clinic changes LPA. The audit checks each of these.
MHRA guidance describes a review of the risk assessment by the Laser Protection Supervisor each year and an audit by the LPA at least every two years. The Association’s certificate runs for 24 months, in line with that two-yearly audit. Local Rules and the risk assessment are still reviewed every 12 months.
Common findings
Gaps that come up in audits and inspections include:
- Generic Local Rules or risk assessments that do not name the clinic’s rooms, devices or staff.
- Documents past their review date, or not updated after a new device or treatment room was added.
- Operators who have not read and signed the current Local Rules.
- Protective eyewear that does not match every wavelength in use, or is scratched or unmarked.
- No warning signage at the entrance to the Laser Controlled Area, or signage left on when no laser hazard is present.
- No treatment register, or treatment records without device settings or skin type.
- No named Laser Protection Supervisor, or a register of Authorised Users that is out of date.
RQIA inspection reports have recorded clinics with no treatment protocols, Local Rules or LPA risk assessment for a laser in use.
Who carries out the audit
Every audit is carried out by a Laser Protection Adviser who has passed the Association’s assessment, holds current certification and is listed on the public Register of Certified Laser Protection Advisers. You can search the Register by name or town, choose an Adviser and book directly from their entry.
Each Adviser holds a certificate with a number beginning LPA-, which can be checked in the same way as an audit certificate. More on the duties a clinic holds is on the guidance for clinics.
Questions
Does my clinic need a laser safety audit?
Clinics using Class 3B or Class 4 lasers or IPL must assess and control the risk of optical radiation under health and safety law. MHRA guidance describes an audit by the Laser Protection Adviser at least every two years, and some licence and registration conditions expect evidence of the LPA’s involvement. An audit provides that evidence and a list of anything to put right.
Who carries out the audit, and how do I check the laser protection advisor?
A Laser Protection Adviser who holds current certification with the Association and is listed on the public Register. Each Adviser has a certificate number beginning LPA-, which anyone can check on the Check a certificate page.
What happens if the audit finds problems?
Each gap becomes an action with an owner and a due date. The clinic marks actions as done in the Laser Safety Register and the Adviser checks them.
Will the Adviser write our Local Rules and risk assessment?
Where they are missing, out of date or not specific to the clinic, the Adviser prepares Local Rules and a laser safety risk assessment for the clinic’s own rooms and devices as part of the audit.
How long is the Certificate of LPA Audit valid?
Twelve months from the date of issue. The Adviser re-audits before it expires, and sooner if devices, rooms or procedures change.
Is the Certificate of LPA Audit a licence?
No. The certificate is issued under the Association’s own scheme and records that a certified Adviser audited the clinic on a given date. It does not replace a local authority licence or registration with a regulator.
Last checked: 21 October 2026. Requirements change. Confirm current conditions with your local authority or regulator.